Q1. What exactly is an RCBO?

A: It’s a combined device that integrates the functions of both a MCB (protecting against overloads/short circuits) and an RCD (safety switch to prevent electric shocks). In contrast to separate RCDs and MCBs, an RCBO provides individual circuit protection, so a fault won’t trip unrelated circuits.  It’s commonly rated at 30mA for shock protection and complies with BS 7671 (18th Edition).

 

Q2. Why would I need an RCBO instead of a fuse or MCB?

A: Unlike fuses/MCBs, an RCBO adds life-saving protection by detecting tiny current leaks (e.g., faulty appliances) and cutting power in milliseconds to prevent shocks or fires.

 

Q3. How do I know if my RCBO is working?

A: Test it monthly with the ‘T’ (Test) button—it should trip instantly. If not, contact a Part P registered electrician.

 

Q4. Are all RCBOs the same?

A: No! As the RCBO is a combination of an MCB and RCD, reference should be made to the relevant technical information regarding these devices.

  • Current Rating Selection (6-50A)
    • 6-16A: Lighting circuits & low-power socket outlets
    • 20-32A: Kitchen sockets, electric ovens, power tools
    • 40-50A: Electric water heaters
  • Breaking Capacity (6kA vs 10kA)
    • 6kA: Suitable for most UK residential properties (standard fault currents)
    • 10kA: Commercial/industrial installations or high-risk areas near substations

For any further queries regarding MK Circuit Protection’s RCBOs, please do not hesitate to contact our technical colleagues at any time.

 

Q5. My old fusebox has no RCBOs—is this safe?

A: It is outdated!  18th Edition regulations require RCBOs for most circuits, upgrading to reduce fire/electrocution risks.

 

Q6. Where can I buy RCBOs of MK Circuit Protection in the UK?

A: You can quickly locate nearby stores via the WHERE TO BUY section on our website. For wholesale customers, please contact our distributor Greenbrook for purchases or submit an inquiry through our webpage.